SWA Series
SWA150 Standard Specifications
| Item | Capacity | 150W | |||||
|---|---|---|---|---|---|---|---|
| Model Name | SWA150-05 | SWA150-12 | SWA150-15 | SWA150-24 | |||
| Input | Rated Input Voltage | AC100 - 240V | |||||
| Input Voltage Range | AC85 ~ 264V | ||||||
| Frequency Range | 47 to 63Hz (rated frequency 50/60Hz) | ||||||
| Input Current | Rated input/ output conditions |
2.4/1.2A(typ) | |||||
| Inrush Current (see Note 1) |
Rated input/ output conditions |
20/40A (max) | |||||
| Efficiency (typ) | Rated input/ output conditions |
75% | 77% | 78% | 79% | ||
| Power Factor (typ) | Rated input/ output conditions |
0.99/0.95 | |||||
| Output (see Note3) |
Rated Output Voltage | 5V | 12V | 15V | 24V | ||
| Output Voltage Variation | Rated output voltage±10% | ||||||
| Rated Output Current | 30A | 13A | 10A | 6.5A | |||
| Output Current Range | 0~100% | ||||||
| Rated Output Power | 150W | 156W | 150W | 156W | |||
| Ripple Noise (mVp-p) (see Note 2) |
Rated input/ output conditions |
120 | 180 | 180 | 240 | ||
| Constant Voltage Accuracy |
Static Input Range |
AC85~264V | ±3% | ||||
| Static Load Range |
0~100% | ||||||
| Time Drift | 10min~8hour | ||||||
| Ambient Temperature Range |
0~+50°C | ||||||
| Others | Output Holdup Time | Rated input/ output conditions |
20ms(min) | ||||
| Startup Time | Rated input/ output conditions |
1000/600ms(typ) | |||||
| Leakage Current | Rated input/ output conditions |
0.5mA (Vin=100VAC)/0.75mA (Vin=240VAC) | |||||
| Additional Functions | Over Current Protection | Detection above 120% of rated current | |||||
| Over Voltage Protection | Detection from 115% to 145% of rated voltage (output cutoff) |
||||||
| Remote Sensing | Provided | ||||||
| Remote On/Off Control | Not provided | ||||||
| Display | Red LED operation indicator | ||||||
| Environmental Conditions |
Operating Temperature Range | 0 to +50°C (without cover) | |||||
| Storage Temperature Range | -25 ~ +85°C | ||||||
| Operating Humidity Range | 30% to 90% (no condensation) | ||||||
| Storage Humidity Range | 30% to 90% (no condensation) | ||||||
| Insulation | Insulation Withstand Voltage (leakage current: 15mA or less) | Between Input and Output, Between Input and Frame |
2,000V AC for 1 minute | ||||
| Between Output and Frame |
500V AC for 1 minute | ||||||
| Insulation resistance | Between Input and Output, Between Input and Frame, Between Output and Frame |
Above 100MW (measured with 500V DC Megger) | |||||
| Structure | Vibration Resistance | 10 to 55Hz, 2G, 1 hour (vibration in X, Y, Z directions, for 3 minutes) with horizontal mounting |
|||||
| Cooling Requirements | Natural air cooling | ||||||
| External Appearance | Open frame (cover and connector are optional) | ||||||
| External Dimensions (mm) | 65W´200D´93H | ||||||
| Weight (g) | 950 | ||||||
| Applicable Standards |
Safety Standards | UL 1950, CSA C22.2 No. 234, TUV (EN60950) certified | |||||
| Conducted Emission | Designed to meet VDE0871 Class A (200-240V AC) Designed to meet FCC Class A (100-120V AC) |
||||||
| Note 1: | At cold start. (More current may flow at restart.) |
| Note 2: | Ripple noise is measured with a 100MHz oscilloscope using a 1:1 probe. |
| Note 3: | All output characteristics are measured at the output connector. |
| * | Rated input/output conditions means that the switching power supply is operated within the rated input voltage, rated output voltage, rated output current, and rated frequency, at an ambient temperature of 25°C and 60% humidity. |