SSG Series

SSG150 Standard Specifications

Item Capacity 150W
Model Name SSG150-05 SSG150-12 SSG150-15 SSG150-24
Input Rated Input Voltage AC100~120V
Input Voltage Range AC85~132V
Frequency Range 47 to 440Hz (rated frequency: 50/60Hz)
Input Current Rated input/
output conditions
3.5A(typ)
Inrush Current
(see Note 1)
Rated input/
output conditions
20A(max)
Efficiency (typ) Rated input/
output conditions
79% 83% 84% 86%
Output
(see Note3)
Rated Output Voltage 5V 12V 15V 24V
Output Voltage Variation Rated output voltage±10%
Rated Output Current 30A 13A 10A 6.5A
Output Current Range 0~100%
Rated Output Power 150W 156W 150W 156W
Ripple Noise (mVp-p)
(see Note 2)
Rated input/
output conditions
120 180 180 240
Constant
Voltage
Accuracy
Static
Input Range
AC85~132V ±3%
Static
Load Range
0~100%
Time Drift 10min~8hour
Ambient
Temperature
Range
0~+50°C
Others Output Holdup Time Rated input/
output conditions
20ms(typ)
Startup Time Rated input/
output conditions
300ms(typ)
Leakage Current Rated input/
output conditions
0.4mA (max)
Switching method, transformer frequency FCC method, approx. 200KHz
Additional Functions Over Current Protection Detection at approx.
105% of rated current
Over Voltage Protection Detection from 115% to 135%
of the rated voltage
Remote Sensing Provided
Remote On/Off Control Not provided
Display LED indicator
Environmental
Conditions
Operating Temperature Range 0 to +50°C
(0 to +40°C with cover)
Storage Temperature Range

-25~+85°C

Operating Humidity Range 30% to 90%
(no condensation)
Storage Humidity Range 30% to 90%
(no condensation)
Insulation Insulation Withstand
Voltage (at normal
temperature and humidity)
Between Input
and Output,
Between Input
and Frame
2,000V AC for 1 minute
Between Output
and Frame
500V AC for 1 minute
Insulation Resistance
(at normal temperature
and humidity)
Between Input
and Output,
Between Input
and Frame, Between
Output and Frame
Above 100MW
(measured with 500V
DC Megger)
Structure Vibration Resistance 10 to 55Hz, 2G, for 1 hour, (vibration in X, Y, Z directions, for 1.5 minutes)
Cooling Requirements Natural air cooling
External Appearance Input/ output connector type with chassis (cover is optional)
External Dimensions (mm) 93x 177x 57(W x D x H)
Weight (g) Approx. 830
Applicable
Standards
Safety Standards UL1950D3, CSA Electrical
Bulletin 1402C certified
Conducted Emission Designed to meet FCC Class B

Note 1: At cold start. (More current may flow at restart.)
Note 2: Ripple noise is measured with a 100MHz oscilloscope using a 1:1 probe.
Note 3: Measurements are made at a point 5cm from the output terminal for all output characteristics, with a 63V 47µF electrolytic capacitor attached at that point.
* Rated input/output conditions means that the switching power supply is operated within the rated input voltage, rated output voltage, rated output current, and rated frequency, at an ambient temperature of 25°C and 60% humidity.