SSG Series
SSG150 Standard Specifications
| Item | Capacity | 150W | |||||
|---|---|---|---|---|---|---|---|
| Model Name | SSG150-05 | SSG150-12 | SSG150-15 | SSG150-24 | |||
| Input | Rated Input Voltage | AC100~120V | |||||
| Input Voltage Range | AC85~132V | ||||||
| Frequency Range | 47 to 440Hz (rated frequency: 50/60Hz) | ||||||
| Input Current | Rated input/ output conditions |
3.5A(typ) | |||||
| Inrush Current (see Note 1) |
Rated input/ output conditions |
20A(max) | |||||
| Efficiency (typ) | Rated input/ output conditions |
79% | 83% | 84% | 86% | ||
| Output (see Note3) |
Rated Output Voltage | 5V | 12V | 15V | 24V | ||
| Output Voltage Variation | Rated output voltage±10% | ||||||
| Rated Output Current | 30A | 13A | 10A | 6.5A | |||
| Output Current Range | 0~100% | ||||||
| Rated Output Power | 150W | 156W | 150W | 156W | |||
| Ripple Noise (mVp-p) (see Note 2) |
Rated input/ output conditions |
120 | 180 | 180 | 240 | ||
| Constant Voltage Accuracy |
Static Input Range |
AC85~132V | ±3% | ||||
| Static Load Range |
0~100% | ||||||
| Time Drift | 10min~8hour | ||||||
| Ambient Temperature Range |
0~+50°C | ||||||
| Others | Output Holdup Time | Rated input/ output conditions |
20ms(typ) | ||||
| Startup Time | Rated input/ output conditions |
300ms(typ) | |||||
| Leakage Current | Rated input/ output conditions |
0.4mA (max) | |||||
| Switching method, transformer frequency | FCC method, approx. 200KHz | ||||||
| Additional Functions | Over Current Protection | Detection at approx. 105% of rated current |
|||||
| Over Voltage Protection | Detection from 115% to 135% of the rated voltage |
||||||
| Remote Sensing | Provided | ||||||
| Remote On/Off Control | Not provided | ||||||
| Display | LED indicator | ||||||
| Environmental Conditions |
Operating Temperature Range | 0 to +50°C (0 to +40°C with cover) |
|||||
| Storage Temperature Range |
-25~+85°C |
||||||
| Operating Humidity Range | 30% to 90% (no condensation) |
||||||
| Storage Humidity Range | 30% to 90% (no condensation) |
||||||
| Insulation | Insulation Withstand Voltage (at normal temperature and humidity) |
Between Input and Output, Between Input and Frame |
2,000V AC for 1 minute | ||||
| Between Output and Frame |
500V AC for 1 minute | ||||||
| Insulation Resistance (at normal temperature and humidity) |
Between Input and Output, Between Input and Frame, Between Output and Frame |
Above 100MW (measured with 500V DC Megger) |
|||||
| Structure | Vibration Resistance | 10 to 55Hz, 2G, for 1 hour, (vibration in X, Y, Z directions, for 1.5 minutes) | |||||
| Cooling Requirements | Natural air cooling | ||||||
| External Appearance | Input/ output connector type with chassis (cover is optional) | ||||||
| External Dimensions (mm) | 93x 177x 57(W x D x H) | ||||||
| Weight (g) | Approx. 830 | ||||||
| Applicable Standards |
Safety Standards | UL1950D3, CSA Electrical Bulletin 1402C certified |
|||||
| Conducted Emission | Designed to meet FCC Class B | ||||||
| Note 1: | At cold start. (More current may flow at restart.) |
| Note 2: | Ripple noise is measured with a 100MHz oscilloscope using a 1:1 probe. |
| Note 3: | Measurements are made at a point 5cm from the output terminal for all output characteristics, with a 63V 47µF electrolytic capacitor attached at that point. |
| * | Rated input/output conditions means that the switching power supply is operated within the rated input voltage, rated output voltage, rated output current, and rated frequency, at an ambient temperature of 25°C and 60% humidity. |