SLM Series
SLM030 Standard Specifications
| Item | Capacity | 30W | |||
|---|---|---|---|---|---|
| Model Name | SLM030-01 | ||||
| Input | Rated Input Voltage | AC100V | |||
| Input Voltage Range | AC90~135V | ||||
| Frequency Range | 48 to 65Hz (rated frequency 50/60Hz) | ||||
| Input Current | Rated input/ output conditions |
0.9A(typ) | |||
| Inrush Current (see Note 1) |
Rated input/ output conditions |
20A(max) | |||
| Efficiency (typ) | Rated input/ output conditions |
65% | |||
| Output (see Note 2) |
Rated Output Voltage | +5V | +12V | ||
| Output Voltage Variation | Fixed | ||||
| Rated Output Current | 2.0A | 2.0A (Peak: 2.8A) see Note 3 | |||
| Output Current Range | 0.1~2.0A | 0.1~2.0A | |||
| Rated Output Power | 30W | ||||
| Ripple Noise (mVp-p) |
Rated input/ output conditions |
60 | 150 | ||
| Constant Voltage Accuracy |
Static Input Range |
AC85~132V | ±5% (Ambient temperature range: 0 to +40°C) | ||
| Static Load Range |
~100% | ||||
| Time Drift | 10min~8hour | ||||
| Ambient Temperature Range |
0~+40°C | ||||
| Others | Output Holdup Time | Rated input/ output conditions |
13ms(typ) | ||
| Leakage Current | Rated input/ output conditions |
0.5mA(max) | |||
| Additional Functions | Over Current Protection | Simple short circuit protection | |||
| Over Voltage Protection | 5.8~6.8V | Not provided | |||
| Remote Sensing | Not provided | ||||
| Display | Not provided | ||||
| Environmental Conditions |
Operating Temperature Range | 0~+40°C | |||
| Storage Temperature Range | -25~+80°C | ||||
| Operating Humidity Range | 30% to 90% (no condensation) | ||||
| Storage Humidity Range | 30% to 90% (no condensation) | ||||
| Insulation | Insulation Withstand Voltage (at normal temperature and humidity) |
Between Input and Output, Between Input and Frame |
1,500V AC for 1 minute | ||
| Between Output and Frame |
500V AC for 1 minute | ||||
| Insulation Resistance (at normal temperature and humidity) |
Between Input and Output, Between Input and Frame, Between Output and Frame |
100MW (measured with 500V DC Megger) | |||
| Structure | Vibration Resistance (when inactive) | 10 to 55Hz, 2.5G, for 1 hour each (vibration in X, Y, Z directions, for 1.5 minutes) | |||
| Shock Resistance | 10G (3 times each in X, Y, Z directions) | ||||
| Cooling Requirements | Natural air cooling | ||||
| External Appearance | Single printed circuit board | ||||
| External Dimensions (mm) | 140W´90D´35H | ||||
| Weight (g) | Approx. 250 | ||||
| Applicable Standards |
Safety Standards | Designed to meet UL 478 and CSA Electrical Bulletin 1402C | |||
| Conducted Emission | Designed to meet FCC Class B and VCCI Class B | ||||
| Note 1: | A higher inrush current than the value indicated may flow at restart. |
| Note 2: | Measurements are made at a point 5cm from the output terminal for all output characteristics, with a 63V 47µF electrolytic capacitor attached at that point. |
| Note 3: | Within 15 seconds |
| * | Rated input/output conditions means that the switching power supply is operated within the rated input voltage, rated output voltage, rated output current, and rated frequency, at an ambient temperature of 25°C and 60% humidity. |