CSJ Series
CSJ015 Standard Specifications
| Item | Capacity | 15W | |||||
|---|---|---|---|---|---|---|---|
| Model Name | CSJ015-05 | CSJ015-12 | CSJ015-15 | CSJ015-24 | |||
| Input | Rated Input Voltage | AC100V/AC120V | |||||
| Input Voltage Range | AC85~132V | ||||||
| Frequency Range | 47 to 440Hz (rated frequency: 50/60Hz) | ||||||
| Input Current | Rated input/ output conditions |
0.4A(typ) | |||||
| Inrush Current (see Note 1) |
Rated input/ output conditions |
30A (max.) at cold start | |||||
| Efficiency (typ) | Rated input/ output conditions |
72% | 73% | 75% | 77% | ||
| Output (see Note3) |
Rated Output Voltage | 5V | 12V | 15V | 24V | ||
| Output Voltage Variation | Rated output voltage±10% | ||||||
| Rated Output Current | 3.0A | 1.25A | 1.0A | 0.65A | |||
| Output Current Range | 0~100% | ||||||
| Rated Output Power | 15.0W | 15.0W | 15.0W | 15.6W | |||
| Ripple Noise (mVp-p) (see Note 2) |
Rated input/ output conditions |
120 | 150 | 150 | 200 | ||
| Constant Voltage Accuracy |
Static Input Range |
AC85~132V | ±3% | ||||
| Static Load Range |
0~100% | ||||||
| Time Drift | 10min~8hour | ||||||
| Ambient Temperature Range |
-10~+60°C | ||||||
| Others | Output Holdup Time | Rated input/ output conditions |
16ms(min) | ||||
| Startup Time | Rated input/ output conditions |
20ms(typ) | |||||
| Leakage Current | Rated input/ output conditions |
0.3mA | |||||
| Additional Functions | Over Current Protection | Detection above 105% of rated current (automatic recovery) |
|||||
| Over Voltage Protection | Detection above 115% of rated voltage (output cutoff) |
||||||
| Remote Sensing | Not provided | ||||||
| Remote On/Off Control | Not provided | ||||||
| Display | Not provided | ||||||
| Environmental Conditions |
Operating Temperature Range (see Note 4) | -10 to +60°C (70% load at 60°C) | |||||
| Storage Temperature Range |
-25~+85°C |
||||||
| Operating Humidity Range | 30% to 90% (no condensation) | ||||||
| Storage Humidity Range | 30% to 90% (no condensation) | ||||||
| Insulation | Insulation Withstand Voltage (at normal temperature and humidity) |
Between Input and Output, Between Input and Frame |
2,000V AC for 1 minute or 2,400V AC for 1 second (leakage current 15mA) |
||||
| Between Output and Frame |
500V AC for 1 minute or 600V AC for 1 second (leakage current 15mA) |
||||||
| Insulation Resistance (at normal temperature and humidity) |
Between Input and Output, Between Input and Frame, Between Output and Frame |
100MW (measured with 500V DC Megger) | |||||
| Structure | Vibration Resistance | 10 to 55Hz, 2G, 1 hour, (vibration in X, Y, Z directions, for 3 minutes) |
|||||
| Cooling Requirements | Natural air cooling | ||||||
| External Appearance | Single printed circuit board | ||||||
| External Dimensions (mm) | 115x 50x 17(W x D x H) | ||||||
| Weight (g) | Approx. 70 | ||||||
| Applicable Standards |
Safety Standards | UL 1950, CSA C22.2 No. 234 Level 3 certified Designed to meet Electrical Appliance and Material Control Law |
|||||
| Conducted Emission | Designed to meet FCC Class B, VCCI Class B |
||||||
| Note 1: | At cold start. (More current may flow at restart.) |
| Note 2: | Ripple noise is measured with a 100MHz oscilloscope using a 1:1 probe. |
| Note 3: | Output characteristics are measured at the output connector. Ripple noise is measured at a point 5cm from the output connector, with a 63V 47µF electrolytic capacitor attached at that point. |
| Note 4: | It may be necessary to derate the output current depending on the operating conditions. Refer to the derated output current for the installation conditions and ambient temperature. |
| * | Rated input/output conditions means that the switching power supply is operated within the rated input voltage, rated output voltage, rated output current, and rated frequency, at an ambient temperature of 25°C and 60% humidity. |