SAMCO-vm05 Series (SHF/SPF, SBT)
Terminal connection diagram

Note 1: Be sure to ground the inverter and motor.
Note 2: The output terminals are multifunctional terminals that can be assigned individually with function codes Cd638 to Cd640.
Note 3: Terminal for upgrading. Normally leave open.
Note 4: Switch the function with function code Cd002. The terminal can be used as an input terminal for various feedback signals.
Note 5: The input terminals are multifunctional terminals that can be assigned individually with function codes Cd630 to Cd637.
Note 6: DCM1 and DCM2 are digital signal common terminals.
Note 7: The alarm signal output terminals are multifunctional terminals that users assign with function code Cd674.
Note 8: SBT-0.75K/1.5K to 7.5K/11K are equipped with a brake resistor as standard. Open the standard resistor when mounting an external brake resistor.
Note 9: SPF-75K is a standard DC reactor.