SAMCO-e Series
Standard Specifications
| Power Supply Type | Single-Phase 200 V System |
Three-Phase 200 V System |
Three-Phase 400 V System |
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | ES- 0.4 K |
ES- 0.75 K |
ES- 1.5 K |
ES- 2.2 K |
ET- 0.4 K |
ET- 0.75 K |
ET- 1.5 K |
ET- 2.2 K |
ET- 3.7 K |
EF- 0.4 K |
EF- 0.75 K |
EF- 1.5 K |
EF- 2.2 K |
EF- 4.0 K |
||
| Output | Applicable motor capacity [kW] |
0.4 | 0.75 | 1.5 | 2.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 0.4 | 0.75 | 1.5 | 2.2 | 4 | |
| Rated capacity [kVA]*1 |
0.99 | 1.6 | 2.82 | 3.81 | 0.99 | 1.6 | 2.82 | 3.81 | 6.28 | 1.04 | 1.73 | 2.77 | 3.81 | 6.03 | ||
| Rated current [A]*2 |
2.6 | 4.3 | 7.4 | 10 | 2.6 | 4.3 | 7.4 | 10 | 16.5 | 1.5 | 2.5 | 4 | 5.5 | 8.7 | ||
| Overload current [A] |
150%, 1 minute | |||||||||||||||
| Rated output voltage |
200V 50/60Hz 220V/60Hz |
380V/50Hz,400V/50Hz, 460V/60Hz |
||||||||||||||
| Input | Rated voltage and frequency | Single-phase 200 V to 240 V, 50/60 Hz | Three-phase 200 V to 230 V, 50/60 Hz |
Three-phase 380 V to 460 V, 50/60Hz |
||||||||||||
| Allowable fluctuation |
Voltage: ± 10%, frequency: ± 5%, voltage imbalance: 3% max. | |||||||||||||||
| Source impedance |
1% or more (Use the optional reactor if less than 1%) | |||||||||||||||
| Protective structure | Shutdown method (IP20) | |||||||||||||||
| Cooling method | Forced air cooling | |||||||||||||||
| Control functions |
Control method V/f control |
Control method V/f control | ||||||||||||||
| High-frequency carrier |
Sine wave PWM (carrier frequency: 1 to 14 kHz)*3 | |||||||||||||||
| Output frequency range | 0.1 to 400 Hz (starting frequency: 0.1 to 20 Hz, variable) | |||||||||||||||
| Frequency setting resolution |
Digital setting |
0.1 Hz (0.1 to 400 Hz) | ||||||||||||||
| Analog setting |
10 bits for 0 to 10 V, 4 to 20 mA, 9 bits for 0 to 5 V for maximum output frequency | |||||||||||||||
| Frequency accuracy | Digital setting |
± 0.01% of output frequency (at -10 to 40°C) | ||||||||||||||
| Analog setting |
± 0.2% of maximum output frequency (at 25° C ±10° C)*4 | |||||||||||||||
| DC braking | Starting frequency (0.2 to 20 Hz), operation time (0.1 to 10 s), braking force (1 to 10 steps) |
|||||||||||||||
| Additional functions | Multi-speed operation, frequency jump, auto alarm recovery, PID control operation, energy-saving operation |
|||||||||||||||
| Operational functions |
Start/stop setting | Operation panel, serial communication (RS485), control circuit terminals |
||||||||||||||
| Frequency command setting | Digital setting |
Operation panel, serial communication (RS485) |
||||||||||||||
| Analog setting |
2 external channels: 0 to 5 V, 0 to 10 V, 4 to 20 mA, external variable resistor (5 kΩ , 0.3 W or higher)/operation panel dial |
|||||||||||||||
| Input signals | Frequency command, forward run command, reverse run command, acceleration/deceleration time setting, free-run stop/ alarm reset, emergency stop, jogging selection, operation signal hold (Digital input: 6 channels (arbitrary allocation available)) (Analog input: 1 channel for voltage, 1 channel for current) |
|||||||||||||||
| Output signals |
Contact output |
Alarm batch contact output (1C contact, 250 VAC, 0.3 A) | ||||||||||||||
| Monitor signals |
Operating, frequency matching, overload alarm, undervoltage, frequency approach (Open-collector output: 1 channel (arbitrary allocation available), Analog output: 1 channel) |
|||||||||||||||
| LED display | Frequency, output current, operating, no-unit alarm, load factor, output voltage, line speed |
|||||||||||||||
| Protection functions | Current limiting, overcurrent shutoff, motor overload, external temperature, undervoltage, overvoltage, momentary power failure, fin overheat, open phase |
|||||||||||||||
| Warning functions | Overvoltage prevention, current limiting during acceleration/deceleration, brake resistor overheat, overload, overheating of radiator fins |
|||||||||||||||
| Ambient temperature | -10 to +50° C (Carrier frequency is to be reduced at +40° C and higher)*5 |
|||||||||||||||
| Storage temperature | -20 to +65° C*6 | |||||||||||||||
| Relative humidity | 90% or less (with no condensation) |
|||||||||||||||
| Operating environment | Indoors at 1,000 m or lower altitude (No direct sunlight, corrosive or inflammable gases, oil mist, or dust) |
|||||||||||||||
- Rated capacity at an output voltage of 220 V for 200 V system, and at an output voltage of 400 V for the 400 V system.
- Rated current should be reduced according to output voltage when input voltage is 400 VAC or higher.
- The maximum carrier frequency varies depending on the rated characteristics and the operating status.
- The maximum output frequency is at 5 V, 10 V, and 20 mA.
- Use the inverter with the carrier frequency set to Cd051 = 90 or lower.
- This temperature is for short periods, such as during transportation.