SAMCO-e Series

Standard Specifications

Power Supply Type Single-Phase 200 V
System
Three-Phase
200 V System
Three-Phase
400 V System
Model ES-
0.4
K
ES-
0.75
K
ES-
1.5
K
ES-
2.2
K
ET-
0.4
K
ET-
0.75
K
ET-
1.5
K
ET-
2.2
K
ET-
3.7
K
EF-
0.4
K
EF-
0.75
K
EF-
1.5
K
EF-
2.2
K
EF-
4.0
K
Output Applicable
motor capacity
[kW]
0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 3.7 0.4 0.75 1.5 2.2 4
Rated capacity
[kVA]*1
0.99 1.6 2.82 3.81 0.99 1.6 2.82 3.81 6.28 1.04 1.73 2.77 3.81 6.03
Rated current
[A]*2
2.6 4.3 7.4 10 2.6 4.3 7.4 10 16.5 1.5 2.5 4 5.5 8.7
Overload current
[A]
150%, 1 minute
Rated output
voltage
200V 50/60Hz
220V/60Hz
380V/50Hz,400V/50Hz,
460V/60Hz
Input Rated voltage and frequency Single-phase 200 V to 240 V, 50/60 Hz Three-phase 200 V to 230 V,
50/60 Hz
Three-phase 380 V to 460 V,
50/60Hz
Allowable
fluctuation
Voltage: ± 10%, frequency: ± 5%, voltage imbalance: 3% max.
Source
impedance
1% or more (Use the optional reactor if less than 1%)
Protective structure Shutdown method (IP20)
Cooling method Forced air cooling
Control
functions
Control method
V/f control
Control method V/f control
High-frequency
carrier
Sine wave PWM (carrier frequency: 1 to 14 kHz)*3
Output frequency range 0.1 to 400 Hz (starting frequency: 0.1 to 20 Hz, variable)
Frequency
setting
resolution
Digital
setting
0.1 Hz (0.1 to 400 Hz)
Analog
setting
10 bits for 0 to 10 V, 4 to 20 mA, 9 bits for 0 to 5 V for maximum output frequency
Frequency accuracy Digital
setting
± 0.01% of output frequency (at -10 to 40°C)
Analog
setting
± 0.2% of maximum output frequency (at 25° C ±10° C)*4
DC braking Starting frequency (0.2 to 20 Hz),
operation time (0.1 to 10 s),
braking force (1 to 10 steps)
Additional functions Multi-speed operation, frequency jump, auto alarm recovery,
PID control operation, energy-saving operation
Operational
functions
Start/stop setting Operation panel, serial communication (RS485),
control circuit terminals
Frequency command setting Digital
setting
Operation panel, serial communication
(RS485)
Analog
setting
2 external channels:
0 to 5 V, 0 to 10 V,
4 to 20 mA, external variable resistor
(5 kΩ , 0.3 W or higher)/operation panel dial
Input signals Frequency command,
forward run command, reverse run command,
acceleration/deceleration time setting, free-run stop/
alarm reset, emergency stop, jogging selection, operation signal hold
(Digital input: 6 channels (arbitrary allocation available))
(Analog input: 1 channel for voltage, 1 channel for current)
Output
signals
Contact
output
Alarm batch contact output (1C contact, 250 VAC, 0.3 A)
Monitor
signals
Operating, frequency matching, overload alarm, undervoltage,
frequency approach
(Open-collector output: 1 channel (arbitrary allocation available),
Analog output: 1 channel)
LED display Frequency, output current, operating, no-unit alarm, load factor,
output voltage, line speed
Protection functions Current limiting, overcurrent shutoff, motor overload, external temperature,
undervoltage, overvoltage, momentary power failure, fin overheat, open phase
Warning functions Overvoltage prevention, current limiting during
acceleration/deceleration, brake resistor overheat, overload,
overheating of radiator fins
Ambient temperature -10 to +50° C
(Carrier frequency is to be reduced at +40° C and higher)*5
Storage temperature -20 to +65° C*6
Relative humidity 90% or less
(with no condensation)
Operating environment Indoors at 1,000 m or lower altitude
(No direct sunlight, corrosive or inflammable gases, oil mist, or dust)
  1. Rated capacity at an output voltage of 220 V for 200 V system, and at an output voltage of 400 V for the 400 V system.
  2. Rated current should be reduced according to output voltage when input voltage is 400 VAC or higher.
  3. The maximum carrier frequency varies depending on the rated characteristics and the operating status.
  4. The maximum output frequency is at 5 V, 10 V, and 20 mA.
  5. Use the inverter with the carrier frequency set to Cd051 = 90 or lower.
  6. This temperature is for short periods, such as during transportation.