SAMCO-e Series

Function Codes

Code
No.
Cd
Function Data Setting resolution Factory preset User’s setting
000 Display selection 1: Frequency (Hz)
2: Output current (A)
7: No-unit display
1 1  
001 Operation command selection 1: Operation panel
2: External terminal signal
3: Communication
1 1  
002 1st speed frequency setting 0: Operation Panel Resistor
1:Operation panell
2: External analog VRF (0 to 5 V)
3: External analog VRF (0 to 10 V or variable resistor)
6: External analog IRF (4 to 20 mA)
10: External analog VRF + IRF
11: External analog VRF - IRF
12: Reserved
13: Reserved
14: Communication
1 0  
003 V/f pattern 1: Linear pattern
2: Square-law decreasing pattern
1 1  
004 Torque boost 0 to 20% (maximum voltage ratio) 0.1% *1  
005 Base voltage 200 V system 0: No AVR
30 to 240 V
1V *1  
400 V system 0: No AVR
30 to 460 V
006 Base frequency 0.1 to 400 Hz 0.1Hz *1  
007 Upper frequency limit 30 to 400 Hz 0.1Hz 60  
008 Lower limit frequency 0.1 to 200 Hz 0.1 Hz 0.1Hz 0.1  
009 Starting method 1: Starting frequency
3: Starting frequency after DC braking
1 1  
010 Starting frequency 0.1 to 20 Hz 0.1Hz 1  
011 Operation start frequency 0 to 20 Hz 0.1Hz 0  
012 Start delay time 0 to 5 sec 0.1 s 0  
013 Braking method 1: Deceleration to stop
2: Deceleration to stop + DC braking
3: Free run stop
1 1  
014 DC braking start frequency 0.2 to 20 Hz 0.1Hz 0.5  
015 DC braking time 0.1 to 10 sec. 0.1 s 2  
016 DC braking force 1 to 10 1 5  
018 Reference acceleration/
deceleration frequency
10 to 120 Hz 0.1Hz *1  
019 1st acceleration time 0 to 999.9 sec. 0.1 s *2  
020 2nd acceleration tim 0 to 999.9 s 0.1 s *3  
023 1st deceleration time 0 to 999.9 s 0.1 s *4  
024 2nd deceleration time 0 to 999.9 sec. 0.1 s *5  
027 Jog acceleration/
deceleration time
0 to 20 s 0.1 s 0.1  
028 Jog frequency 0.1 to 60Hz 0.1Hz 5  
029 1st speed frequency 0 to 400Hz 0.1Hz 0  
030 2nd speed frequenc 0 to 400Hz 0.1Hz 10  
031 3rd speed frequency 0 to 400Hz 0.1Hz 20  
032 4th speed frequency 0 to 400Hz 0.1Hz 30  
033 5th speed frequency 0 to 400Hz 0.1Hz 40  
034 6th speed frequency 0 to 400Hz 0.1Hz 50  
035 7th speed frequency 0 to 400Hz 0.1Hz 60  
036 8th speed frequency 0 to 400Hz 0.1Hz 0  
037 Jump bottom frequency 0 to 400Hz 0.1Hz 0  
038 Jump top frequency 0 to 400Hz 0.1Hz 0  
043 Output current limiting 0: No function
50 to 200%
1% 150  
044 Electrothermal level setting 0: No function
20 to 105%
1% 100  
045 Output current limiting
during constant
power operation
0: No
1: Yes (Currently selected acceleration/deceleration time)
2: Yes (Acceleration/Deceleration time = Cd019,
Cd023: 1st acceleration/deceleration time)
3: Yes (Acceleration/Deceleration time = Cd020,
Cd024: 2nd acceleration/deceleration time)
1 0  
047 Auto alarm recovery 0: No auto alarm recovery function
1: Auto alarm recovery function
1 0  
049 Duty cycle of brake resistor 0: No brake resistor
2 to 25% ED
1%ED *  
050 Direction of rotation of motor
Note: Cd130 for direction from the operation panel command
1: Forward and reverse run
2: Forward run only
3: Reverse run only
1 1  
051 Carrier frequency 0 to 130 1 *1  
052 Motor type 1: General-purpose motor
2: Motor designed specifically for inverter
1 1  
054 Bias frequency (VRF) -99.9 to 400 Hz (frequency at 0 V) 0.1Hz 0  
055 Gain frequency (VRF) -99.9 to 400 Hz (frequency at 5 or 10 V) 0.1Hz 60  
056 Approach frequency 0 to 400 Hz 0.1Hz 10  
057 Frequency matching range 0 to 10 Hz 0.1Hz 0  
058 Multiple for no-units display 0 to 99.99 (multiple of the output frequency) 0.01 1  
059 Display selection 1: No units (multiple of CD058)
2: PID feedback frequency [Hz]
3: Load factor [%]
4: Output voltage [V]
5: Reserved
6: Fin temperature [°C]
7-13: Reserved
1 1  
062 Bias frequency (IRF) -99.9 to 400 Hz
(frequency at 4 mA)
0.1 Hz 0  
063 Gain frequency (IRF) -99.9 to 400 Hz
(frequency at 20 mA)
0.1Hz 60  
066 V•f separate function selection 1: V/f comparison
2: Complete separation
1 1  
070 ES input terminal function 1: NO external thermal signal
2: NC external thermal signal
1 1  
071 Motor control mode selection 1: V/F control mode
3: Internal PID control mode
7: Auto energy-saving mode
11: V•f separate control
1 1  
072 to 082 Reserved        
083 External analog input
Filter time constant
1 to 500 (set value: 1 = 10 ms) 10ms 10  
084 Copy function
(Option)
1: Transfer the current code data to the operation panel
2: Transfer the operation panel memory to the inverter
1 0  
096 Function lock 0: Code data changeable (No lock function)
2: Code data unchangeable
(except Cd096 and Cd028 to Cd036)
1 0  
098 Reading alarm data 0
1: Read start
9: Record erase
1 0  
099 Data initialization 0
1: Factory setting data initialization
1 0  
120 Analog input switchin
(for both of the PID and the energy saving functions)
0: No analog input
1: External analog VRF (0 to 5 V)
2: External analog VRF (0 to 10 V or variable resistor)
5: External analog IRF (4 to 20 mA)
1 0  
122 PID control proportional gain 0 to 99.99 0.01 0.1  
123 PID control integral gain 0 to 99.99 0.01 0.1  
124 PID control differential gain 0 to 99.99 0.01 0  
125 Feedback input filter time 1 to 500 (set value 1 = 10 ms) 10ms 10  
126 Internal analog output function 0: No function
1: Set frequency
2: Output frequency
3: Output current
4: Reserved
5: Fin temperature
6: Load factor (Electrothermal level integrated value)
7: Output of converted analog input value
(VRF control circuit terminal input)
8: Output of converted analog input value
(IRF control circuit terminal input)
9: Output voltage
10: Load factor (Percentage in terms of rated current)
12:Reserved
1 0  
127 Internal analog output coefficient 0 to 20X by 0.01 1  
130 Direction of rotation of motor (Operation panel)

 

1: Forward
2: Reverse
1 1  
136 The Bias Frequency (for theFrequency Control
on the operation panel).

 

-99.9 to 400 Hz 0.1Hz 0  
137 The Gain Frequency (for the Frequency Control
on the operation panel).

 

-99.9 to 400 Hz 0.1Hz 60  
140 Changed code display function 0
1: Display differences from factory preset
1 0  
142 Message checksum 0: No
1: Yes
1 1  
144 Pull-up/down function 0: No
1: Yes
1 0  
146 Communication function 0: No function
1: Serial communication function
1 0  
147 Inverter No. 1 to 32 1 1  
148 Communication speed 1: 1200bps
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
1 3  
149 Parity bit 0: None
1: Odd
2: Even
1 1  
150 Stop bit 1: 1 bit
2: 2 bits
1 1  
151 End bit 0: CR, LF
1: CR
1 0  
152 Select INV response mode for specific commands 0: Enable response
1: No response (enable Error response)
2: No response (disable Error response)
1 0  
630
631
632
633
634
635
636
637
Selection of input terminal DI1
Selection of input terminal DI2
Selection of input terminal DI3
Selection of input terminal DI4
Selection of input terminal DI5
Selection of input terminal DI6
Reserved
Reserved
0: Not used 1: FR 2: RR 3:2DF 4:3DF 5: MBS
6: ES 7: RST 8: AD2 9: Reserved
10: JOG 11: FR+JOG 12: RR+JOG
13: FR+AD2 14: RR+AD2 15,16: Reserved
17: FR+2DF 18: RR+2DF 19: FR+3DF
20: RR+3DF 21: FR+2DF+3DF
22: RR+2DF+3DF 23: FR+AD2+2DF
24: RR+AD2+2DF 25: FR+AD2+3DF
26: RR+AD2+3DF 27: FR+AD2+2DF+3DF
28: RR+AD2+2DF+3DF 29 to 35: Reserved
36: IF 37: 5DF 38: HD 39 to 45 Reserved
46: PID 47 to 64: Reserved 65: 2DF+AD2
66: Reserved 67: 3DF+AD2
68 to 99: Reserved
1 1
2
3
4
5
7
 
638 Selection of output terminal DO 0: Not used
1: In operation
2: Low voltage
3: Reserved 4: In operation 2
5: Frequency matching (1st speed frequency)
6: Frequency matching (1st to 8th speed frequencies)
7: Frequency approach 8: Reserved
9: Electrothermal level signal (Electrothermal 80%)
10: Fin heat prediction signal
11: Reserved 12: Reserved
13: DC braking
14: Lower frequency limit matching
15: Upper frequency limit matching
16: Reserved 17: Reserved
18: FR signal 19: RR signal 20: 2DF signal
21: 3DF signal 22: AD2 signal 23:Reserved
24: JOG signal 25: MBS signal 26: ES signal
27: RST signal 28 to 99:Reserved
1 1  
641 Missing phase detection function 0: Missing input phase detection is invalid,missing output phase detection is invalid.
1: Missing input phase detection is valid,
missing output phase detection is invalid.
2: Missing input phase detection is invalid,
missing output phase detection is valid.
3: Missing input phase detection is valid,
missing output phase detection is valid.
1 2  
642 Overvoltage stalling prevention function 0: Overvoltage stalling prevention function inactive.
1: Overvoltage stalling prevention function active.
1 1  
643 Feedback signal break detection time 0 to 99 99: No function 0.01 s 5  

:The setting cannot be changed during operation.
*1 Typical constants for each model are entered.
*2 to 5 See the following table:

*2
Cd019
*3
Cd020
*4
Cd023
*5
Cd024
5 10 5 10