Inverter Options
Discharge Resistor Support List
200 V Series
| Inverter Type |
External Brake Resistor |
| Resistance (Ω ) |
Capacity* (W) |
Model |
| ET-0.4K,ES-0.4K |
220 or higher |
100 |
EA120R221J-300 |
| SBT-0.75K/1.5K,ET-0.75K,ES-0.75K |
120 or higher |
150 |
EA220R121J-300 |
| SBT-1.5K/2.2K,ET-1.5K,ES-1.5K |
60 or higher |
300 |
EC300R600J-300 |
| SBT-2.2K/3.7K,ET-2.2K,ES-2.2K |
60 or higher |
300 |
EC300R600J-300 |
| SBT-3.7K/5.5K,ET-3.7K |
40 or higher |
400 |
EC400R400J-300 |
| SBT-5.5K/7.5K |
20 or higher |
800 |
EC800R200J-300 |
| SBT-7.5K/11K |
20 or higher |
800 |
EC800R200J-300 |
400 V Series
| Inverter Type |
External Brake Resistor |
| Resistance (Ω ) |
Capacity* (W) |
Model |
| EF-0.4K |
1000 or higher |
80 |
EA80R102J-300 |
| EF-0.75K |
700 or higher |
100 |
EA120R701J-300 |
| SHF-1.5K/SPF-2.2K,EF-1.5K |
320 or higher |
200 |
EA220R321J-300 |
| SHF-2.2K/SPF-4.0K,EF-2.2K |
160 or higher |
400 |
EC400R161J-300 |
| SHF-4.0K/SPF-5.5K,EF-4.0K |
120 or higher |
600 |
EC600R121J-300 |
| SHF-5.5K/SPF-7.5K |
80 or higher |
800 |
EC800R800J-300 |
| SHF-7.5K/SPF-11K |
60 or higher |
1000 |
EC1000R600J-300 |
| SHF-11K/SPF-15K |
40 or higher |
1500 |
EC800R200J-300× 2 |
| SHF-15K/SPF-18.5K |
40 or higher |
1500 |
EC800R200J-300× 2 |
-
In this example, the maximum usage rate of the brake resistor is assumed to be 10%ED.
In the case of these examples, set 10%ED or lower to Cd049 (brake resistance usage rate) for protection of brake resistor.