Inverter Options

Discharge Resistor Support List

200 V Series
Inverter Type External Brake Resistor
Resistance (Ω ) Capacity* (W) Model
ET-0.4K,ES-0.4K 220 or higher 100 EA120R221J-300
SBT-0.75K/1.5K,ET-0.75K,ES-0.75K 120 or higher 150 EA220R121J-300
SBT-1.5K/2.2K,ET-1.5K,ES-1.5K 60 or higher 300 EC300R600J-300
SBT-2.2K/3.7K,ET-2.2K,ES-2.2K 60 or higher 300 EC300R600J-300
SBT-3.7K/5.5K,ET-3.7K 40 or higher 400 EC400R400J-300
SBT-5.5K/7.5K 20 or higher 800 EC800R200J-300
SBT-7.5K/11K 20 or higher 800 EC800R200J-300
400 V Series
Inverter Type External Brake Resistor
Resistance (Ω ) Capacity* (W) Model
EF-0.4K 1000 or higher 80 EA80R102J-300
EF-0.75K 700 or higher 100 EA120R701J-300
SHF-1.5K/SPF-2.2K,EF-1.5K 320 or higher 200 EA220R321J-300
SHF-2.2K/SPF-4.0K,EF-2.2K 160 or higher 400 EC400R161J-300
SHF-4.0K/SPF-5.5K,EF-4.0K 120 or higher 600 EC600R121J-300
SHF-5.5K/SPF-7.5K 80 or higher 800 EC800R800J-300
SHF-7.5K/SPF-11K 60 or higher 1000 EC1000R600J-300
SHF-11K/SPF-15K 40 or higher 1500 EC800R200J-300× 2
SHF-15K/SPF-18.5K 40 or higher 1500 EC800R200J-300× 2
  • In this example, the maximum usage rate of the brake resistor is assumed to be 10%ED.
    In the case of these examples, set 10%ED or lower to Cd049 (brake resistance usage rate) for protection of brake resistor.
    If %ED is set to 10%ED or higher, increase the brake resistance capacity proportionally.